Printing RFID Tag Errors
618
Message Cause and Countermeasure
Countermeasure
Check the media.
READ ONLY ERROR Only for UHF
Cause
1. Tried to write to a write-locked tag.
2. Tried to write to a tag when the write power is low.
Countermeasure
1. Use media that is not locked.
2. Adjust [Write Power]/[Read Power].
DIFFER TAG KIND Only for ISO/IEC 15693, ISO/IEC 14443 Type A, FeliCa
Cause
Incorrect tag type is specified.
Countermeasure
Check the tag type, and specify the correct tag type.
LOST HANDLE ERR Only for ISO/IEC 15693, ISO/IEC 14443 Type A, FeliCa
Cause
Failed to acquire the ID.
Countermeasure
The radio wave condition needs to be improved. Increase the Read
Power level.