External Signal (EXT) Interface
760
Pin
No.
I/O Description Electric Conditions
(Voltage, Current (Max))
6 Output
Print Done/Print End signal (PREND)
Outputs a signal when the media print is
completed.
Withstand voltage 50 V
Sink current 50 mA
7 Input
Reprint signal (PRIN2)
Prints the previously printed content again
when a low signal is detected.
High: high impedance
Low: more than -15 mA, 0 V
8 Input External power supply 5 V
9 Output
Offline
Outputs a low signal when the printer is in
Offline mode.
Withstand voltage 50 V
Sink current 50 mA
10 Output
Ribbon Near End
Outputs a high signal when the ribbon near
end is detected.
Withstand voltage 50 V
Sink current 50 mA
11 - - -
12 - +24 V ± 10% 2 A
13 - Vcc +5 V 500 mA
14 - - -
* Output
Wait signal for dispense completion
Outputs a low signal when the dispense is
completed.
You can set the pin number for output
through the [Settings] > [Interface] >
[External I/O] > [Signals] > [Outputs] menu.
Withstand voltage 50 V
Sink current 50 mA
* Output
Label Near End signal
Outputs a high signal when the label near
end is detected.
You can set the pin number for output
through the [Settings] > [Interface] >
[External I/O] > [Signals] > [Outputs] menu.
*This feature is supported on printers from
serial number 6B~ and above.
Withstand voltage 50 V
Sink current 50 mA

Table of Contents