PN 9001024
Rev. B Jan. 2000
Page 6-26
SATO CL608 & CL612 SERVICE MANUAL
SECTION 6 – Replacement Procedures
STEP PROCEDURE
1. Switch the printer OFF and disconnect the power cable.
2. Remove (3) screws holding the left side cover to the printer. Raise the
access door and loosen the (2) screws on the inside top of the printer. Lift
off the left side cover to expose the main PCB. Refer to Section 4-2.
3. Raise the main cover and remove the ribbon if installed. Fig. 6-53
4. Remove the sensor mounting screw Figs. 6-54 & 6-55
5. Unplug the SEN4 connector from the PCB and pull the sensor cable and
connector through the frame hole.
Figs. 6-56 & 6-57
6. Remove (2) screws holding the sensor to the bracket. Figs. 6-58 & 6-59
7. Replace sensor and reattach to the mounting bracket. Feed new sensor
connector back through the frame hole and reattach SEN4 on the PCB.
Attach the sensor bracket to the frame insuring alignment pin is in
correctly. Fig. 6-54
8. Replace the left side cover and reconnect the power cable.
The Ribbon Motion Sensor is easily replaced for service.
Fig. 6-53
RAISE THE
MAIN COVER
6-10 Replacing the Ribbon Motion Sensor