PN 9001024
Rev. B Jan. 2000
Page 4-7
SATO CL608 & CL612 SERVICE MANUAL
SECTION 4 – Electrical Checks and Adjustments
4-5 Pitch Potentiometer (User Adjustment)
STEP PROCEDURE
1. Turn the power ON while holding the FEED button.
2. Release the button when the printer emits a sound signal and the
following message is displayed.
3. Use the LINE key to select Small or Large print size.
4. Initiate test print by pressing the FEED key.
5. The printer will start printing. To pause, press FEED key again. Fig.
4-8 (Generated Test Print)
6. In the pause phase, adjust the print position with VR3 potentiometer
(located underneath a flip-down cover on the front panel). The
adjustment range is +/- 3.75 mm. Fig. 4-9
7. Press FEED button to resume printing. Check the print position and
repeat STEP 4 as necessary.
8. After the adjustment, turn the power OFF.
VR3
Fig 4-9
POTENTIOMETERS ARE LOCATED
UNDERNEATH A FLIP-DOWN COVER
ON THE FRONT PANEL
USER TEST PRINT
Small large
TEST PRINT
Fig 4-8