EasyManua.ls Logo

SATO CL608 - Electrical Checks and Adjustments; Electrical Checks Overview

SATO CL608
183 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PN 9001024
Rev. B Jan. 2000
Page 4-1
SATO CL608 & CL612 SERVICE MANUAL
Electrical Checks and Adjustments
4-1 Overview
This chapter describes how to check CL608/612 voltage levels and adjust threshold
sensor voltages.
The power supply converts 125 VAC into regulated DC voltages. The printer uses:
+5V and +24V. These DC voltages are not adjustable, however you can measure
these DC voltages at test points located on the PCB. If a voltage is out of
specification, the power supply must be replaced. Section 4-3 contains procedures
for measuring DC voltage levels. Power supply removal and replacement procedures
are located in Section 6-5.
You can adjust threshold voltage levels for label sensors. These adjustments are
made to allow for variations in the characteristics of the labels used with the printer.
If you cannot calibrate the label sensor voltage level within the specified voltage
range, you should reposition the label sensor by following the adjustment procedures
included in this section. After completing the label sensor adjustment procedures,
perform the label sensor voltage level adjustment procedure.
You can check or adjust:
Power Supply
Label Sensors
Ribbon Sensor
Pitch Offset
Label Positions
4
Section
Checks and adjustments in this section require standard metric tools.
Other equipment is listed where needed.