SATO CL608 & CL612 SERVICE MANUAL
SECTION 4 Electrical Checks and Adjustments
4-6 Offset Adjustment (User Adjustment)
The Offset Adjustment sets the position that the label is feed out to. This will
affect the tear off cut, of dispenser positions if being used.
VR2 can be used to adjust the position +/- 3.75 mm.
VR2
POTENTIOMETERS ARE LOCATED
UNDERNEATH A FLIP - DOWN COVER
ON THE FRONT PANEL