PN 9001024
Rev. B Jan. 2000
SECTION 2 – Configuration
Page 2-10
SATO CL608 & CL612 SERVICE MANUAL
2.3 Printer Adjustments
The LCD Panel on the CL608/CL612 printer is used in conjunction with the LINE and
FEED switches by the operator to manually enter printer configuration settings. Many of
the settings can also be controlled via software commands and in the case of conflict
between software and control panel settings, the printer will always use the last valid
setting. If you load a label job that includes software settings and then enter a new setting
via the operation panel, the manually set values will be used by the printer. If you set the
values manually and then download a job with software settings, the software settings will
be used.
user test print
small large
OnLINE
qty: 000000
default setting
completed
advanced mode
setup
user download
Power On
POWER
POWER+FEED
POWER+LINE
POWER+FEED +
DSW2-7 = ON
POWER+FEED +
LINE
Normal/User Mode
Print Test Labels
Advanced Mode
Settings and
Adjustments
Load SATO
Default Settings
Download User
Defined Protocol
Codes
Refer to
Page 2-25
Refer to
Page 2-11
Refer to
Page 2-9
Refer to
Page 2-14
Refer to
Page 2-5
alt. protocol
default complete
OnLINE
Qty: 000000
RECEIVE BUFFER
Hex Dump Label
Refer to Page 2-2
POWER+LINE+FEED+
DSW2-7 = ON
POWER+DSW2-4 = ON
Print Hex
Dump Label
Reset to SATO
Default Protocol
Codes
Refer to
Page 2-4
DEFAULT SETTING
COMPLETED
POWER+LINE +
FEED
Refer to
Page 2-9