EasyManua.ls Logo

SATO CL608 - Preparation for Procedures

SATO CL608
183 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PN 9001024
Rev. B Jan. 2000
Page 4-2
SATO CL608 & CL612 SERVICE MANUAL
SECTION 4 – Electrical Checks and Adjustments
4-2 Steps Prior to Some Procedures
Some adjustments in this section require access to potentiometers and the test point
connector located on the main PCB. Remove the LH cover for accessing the main PCB.
STEP PROCEDURE
1. Switch the printer OFF.
2. Remove (3) screws holding the left side cover to the printer.
Raise the access door and loosen the (2) screws on the inside top
of the printer. Lift off the left side cover to expose the main PCB.
Fig. 4-1 & 4-2.
Refer to the appropriate sub-section to begin adjustments.
REMOVE (3) SCREWS
Fig 4-1
Fig 4-2
RAISE THE ACCESS
DOOR AND LOOSEN
(2) SCREWS ON THE
INSIDE TOP OF THE
PRINTER
ELECTRONICS
COMPARTMENT