SECTION 3 Interface Specifications
3-4 RS232C Serial Interface (Cont.)
Cable Requirements
* This connection at the host side of the interface would depend upon the pin that is being
used as the Ready/Busy signal by the driving software. Typically, on a PC, it would be either
CTS (pin 5) or DSR (pin 6) on a DB-25 connector.
Data Streams
Once the flow control method has been chosen for the RS232C interface, the data
stream must be sent in a specific manner. The STX and ETX Control characters
must frame the data stream.
<STX><ESC>A..Job#1..<ESC>Z<ETX><STX><ESC>A..Job#n..<ESC>Z<ETX>
NOTE: All characters, including STX, ESC and ETX are in ASCII.
TSOHNOITCENNOCRETNIRETNIRP
GF)dnuorGemarF(GF1
DR)ataDevieceR(DR3
)dneSottseuqeR(STR4
)dneSotraelC(STC5
)ydaeRteSataD(RSD6
*)ydaeRlanimreTataD(RTD02
GS)dnuorGlangiS(GS7