IPE100 indicator NU-IPE100-IO-USER-E-0212
23
9. DISPLAY OF METROLOGIC DATA (inFO)
The indicator is fitted with a function named “INFO”, thanks to which it is possible to view the configuration metric data:
- First range capacity, first range minimum weigh, first range division.
- Second range capacity, second range minimum weigh, second range division.
- Third range capacity, third range minimum weigh, third range division.
NOTES:
- The minimum weigh corresponds to 20 net weight divisions.
- The data of the second and third range appear only if actually configured.
To display the metrologic data:
- Press in sequence the 2ndF and C key
- “METROLOGIC INFORMATION” is displayed
- The display will show the number of the scale, the type of displayed data and its value.
- Press the F6 key to quickly scroll the following data
- Press the F7 key to quickly scroll the previous data backwards.
- Press the C key to quickly return to weighing.
10. FILLING IN THE INPUT TEXT
The indicator offers the possibility of using 15 CONFIGURABLE INPUT TEXTS (for example LOT, OPERATOR, SHIFT,
etc.), each made up of 16 heading characters and 32 content characters.
When entered in the TECHNICAL SETUP (see F.ModE >> tXt “Input text configuration” parameter, TECHNICAL
MANUAL.), these may be printed later on, if programmed in the printouts; or these may be used as a reminder.
To manually fill in the input texts it is possible to proceed in two ways:
1) If one knows the memory storage position (from 0 to 14) of the text to be modified, type the number, followed by
the F4 key: now enter the text and confirm with ENTER (the indicator returns to the weighing phase).
2) By pressing for an instant the F4 key, one accesses the complete list of the texts, for example:
- The LCD display shows “in. XX” in the first line, in which XX is the index of the free text (from 0 to 14) and THE
HEADING on the second line (or “Empty…” if empty).
- Use the arrow keys to select the text to be filled in and press ENTER: now one can enter the alphanumeric
text in the second line of the LCD display, (see chapter 4.1.2 ENTERING ALPHANUMERIC TEXT).
- Press ENTER to store and pass on to the following stored TEXT; by confirming the last entered text one returns
automatically to the weigh functioning; it is possible to exit also with the C key while in the text selection
modification phase.
NOTE:
• The entered texts remain in storage until these are substituted or cancelled.
• If no text has been configured, the pressing of the F4 key has no effect.
• Through specific print macros, it’s possible to automatically cancel the contents of all the texts, right after their printing
(TECHNICAL MANUAL.).
• For information on the entry of the alphanumeric texts, see section “4.1.2 ENTERING ALPHANUMERIC TEXT”.
10.1 QUICK MODIFICATION OF AN INPUT TEXT
By linking the number of a specific input text to the function 114 (preamble function in the << F.KEYS >> step, TECHNICAL
MANUAL.), it is possible to access directly to the modification of it with a direct key, for example F1 key to quickly access
the text 0, and F2 key to quickly access the text 1.