IPE100 indicator NU-IPE100-IO-USER-E-0212
38
Confirm with ENTER or press another key to cancel.
• If no input weigh has been made, if one then enters the menu of the “open” weighs, the indicator will show on the
LCD display “NO OPEN WEIGHS IN INPUT” and will emit a prolonged sound; then it will cancel the weigh and return
to weighing.
13.4 CONDITIONS FOR TOTALISATION
With APPROVED instrument:
- the INPUT or OUTPUT weigh functions with a minimum weight of 20 divisions and reactivates according to how the
F.ModE >> rEACt. “REACTIVATIONS” parameter of the TECHNICAL SETUP has been programmed (RIF.MAN.T.), in
other words the weight movement or passage by zero of the weight; furthermore the F6 key excludes the F7 and the
printout keys and vice versa.
- the totalisation excludes the simple print function and vice versa.
With NON APPROVED instrument:
- the INPUT or OUTPUT weigh functions with a weight greater than zero and reactivates according to how the F.ModE
>> rEACt. “REACTIVATIONS” parameter of the TECHNICAL SETUP (TECHNICAL MANUAL.) has been programmed;
furthermore the F6 key excludes the F7 key and vice versa.
- the totalisation does not exclude the simple print function.
13.5 ADDITIONAL TARE FUNCTION
This function is useful if one wants to calculate the loaded/unloaded weight at the net of a tare added to the weight of the
vehicle taken into consideration.
By enabling the function in the F.ModE >> totAL >> Add.tAr step, it’s possible to have that, upon the output weigh, one is
asked to enter an additional tare, which will be subtracted from the loaded/unloaded weight value in the weigh.
After the pressing of the F7 key and the selection of the “open” weigh in input, one enters the calculator environment (the
LCD display shows the message “ADDITIONAL TARE”).
Procedure:
With the numerical keyboard enter the first value then
• Press Fn in order to consider this value as an additional tare
or
• Press F1 to add, F2 to multiply, F3 to subtract:
- With the numeric keyboard enter the second value of the operation.
- PRESS ENTER: the result will be shown for a few seconds on the display.
The printing of the “CALCULATOR” print function will not be made, but one proceeds with the printing of the output weigh.
The result of the additional tare is automatically subtracted from the loaded or unloaded weight.
13.6 TOLERANCE WEIGHING FIELD
It is possible to establish a weight interval (in between 0 and the scale capacity) for executing an input or output weigh;
outside this interval, the operation is not accepted (when the F6 or F7 key is pressed the LCD display shows the “WEIGHT
OUT OF THRESHOLD” message for a few seconds.
SETTING OF WEIGHT THRESHOLD:
• Through the 500 function, combinable with the desired key (<< F.KEYS >> step, TECHNICAL MANUAL.), it’s possible
to access the “thr.hi" menu (Maximum Threshold Setting): set the upper totalisation threshold and press ENTER.
• Through the 501 function, combinable with the desired key (<< F.KEYS >> step, TECHNICAL MANUAL.), it’s possible
to access the “thr.Lo" menu (Minimum Threshold Setting): set the lower totalisation threshold and press ENTER.
NOTES:
- By setting 0 in the maximum threshold, it’s possible to totalise up to the maximum capacity of the scale.
- By setting 0 in both thresholds, the functions are disabled.
- The totalisation field is valid for all totalisation types (input/output and single weigh).