16.2.2 STRING FORMAT (WEIGHT/ID)
The PID string contains all the information regarding the executed weigh.
DESCRIPTION OF THE PID STRING:
[II]PIDSS,B,LLLLLLLLLLUU,YYTTTTTTTTTTUU,(ID | NO) <CR or CRLF>
in which: [II] 485 address (only in the case of 485 transmission mode)
SS US instable weight
ST stable weight
OL weight out of range (greater)
UL weight out of range (lower)
, comma character, ASCII 044
B number of selected channel
, comma character, ASCII 044
LLLLLLLLLL gross weight on 10 digits
UU unit of measure
, comma character, ASCII 044
YY 2 spaces in the case of null tare or semiautomatic tare, PT in the case of preset tare
TTTTTTTTTT tare weight on 10 digits
, comma character, ASCII 044
ID XXXXX-YYYYYY or “NO”: weigh not stored in the alibi memory; the gross weight is
negative or unstable.
<CR or CRLF> Terminator, ASCII 13 and ASCII 10 characters
16.2.3 WEIGH READING
Command:
[II]ALRDXXXXX-YYYYYY <CR o CRLF>
in which [II] 485 address (only in the case of 485 transmission mode)
XXXXX rewriting number, from 0 up to 255.
- ASCII 045 character
YYYYYY ID code
<CR o CRLF> terminator, ASCII 13 and ASCII 10 characters
Instrument answer:
[II]B,LLLLLLLLLLUU,YYTTTTTTTTTTUU <CR o CRLF>
in which: [II] 485 address (only in the case of 485 transmission mode)
B number of selected channel
, comma character, ASCII 044
LLLLLLLLLL gross weight on 10 digits
UU unit of measure
, comma character, ASCII 044
YY 2 spaces in the case of null tare or semi automatic tare, PT in the case of preset tare
TTTTTTTTTT tare weight on 10 digits
<CR o CRLF> Terminator, ASCII 13 and ASCII 10 characters
16.2.4 ALIBI MEMORY CANCELLATION (only with non approved instrument)
Command:
[II]ALDL <CR o CRLF>
in which [II] 485 address (only in the case of 485 transmission mode)
Instrument answer:
[II]ALDLOK <CR o CRLF> if the cancellation has been carried out effectively