Block G : Filter settings
G 01 I Display
Range: 0,0...600,0 s Default: 3,0 s
Feed rate display
G 02 I Analog output
Range: 0,0...600,0 s Default: 3,0 s
Feed rate analog output
All filters are of the 1st order type
(exponential), i.e. after abrupt
change of signal, approx. 2/3
of the limit value are reached
after the set time.
Longer times stabilize display
but reduce update rate.