L 09 Baud rate
Range: 2400
4800
9600
19200
38400
Preconfigured value: 9600
Modbus baud rate.
L 10 Data Format
Range: 8-E-1
8-0-1
8-N-2
8-N-1
Preconfigured value: 8-E-1
Modbus data format (data bits-parity-stop bits).
L 11 Physics
Range. RS485 2-wire
RS485 4-wire
Original value: RS485 2-wire
Determines whether the Modbus interface is operated as a 2-wire or a 4-wire bus.
L 12 ADDRESS
Range: 0...126 Preconfigured value: 16
Profibus DP-Slave address.
L 13 FLOAT-FORMAT
Range: IEEE
SIEMENS-KG
Preconfigured value: IEEE
Determines the display of the floating point value for the PROFIBUS DP protocol.
L 14 ADDRESS
Range: 0...63 Preconfigured value: 63
DeviceNet slave address.
L 15 Baud rate
Range: 125k
250k
500k
Preconfigured value: 125k
DeviceNet baud rates.
INTECONT® Satus Operating Manual BV-H2346GB / 0833 51