Object directory of the encoder
ATM60-Cxx 03/2007 39
Bit Function Bit = 0 Bit = 1
reached
4 Battery charge OK too low
5
Reference point
reached
not reached
6-11 reserved
12-15 not used
9.2.1.22 Object 6506 hex: warnings supported
Description
This object defines the warnings which are supported by the encoder.
Explanation
Bit Function Bit = 0 Bit = 1
0
Speed monitoring
not
supported
supported
1
Optical monitoring reserve
not
supported
supported
2
CPU watchdog status
not
supported
supported
3
Operating time
not
supported
supported
4
Battery charge
not
supported
supported
5
Reference point
not
supported
supported
6-11 reserved
12-15 not used
Warnings on a grey background are not supported by the encoder.
9.2.1.23 Object 6507 hex: profile and software version
Description
This object contains the profile and software version of the encoder.
In work