FLOWSIC600 · Operating Instructions · 8010458 V 2.0 · © SICK MAIHAK GmbH 53
Commissioning
4.5
Field Setup
The MEPAFLOW600 CBM software “Field setup” wizard guides through the parameter
configuration during the commissioning of the FLOWSIC600. The wizard consists of 8
pages. For checking and configuration refer to the “Instrument Data Sheet” of the
FLOWSIC600, which is included in the Manufacturer Data Record (MDR) (example see
Figure 21).
b
To start the Field setup, choose “Tools / Field Setup” from the menu.
b
Follow the instructions on screen step by step.
Figure 21 Example of an “Instrument Data Sheet” as contained in the MDR
The parameter changes performed in the Field setup wizard require the User
Access Level Authorized operator” (see
pg.48, 4.3.2).
0
1 54
2 55 12 .. 28,8 V DC < 1W
3 56
4 57
5 58
6
7
8 59
9
60 Ambient temperature °C
10 Inner connection diameter mm 61
11 Overall length (A) mm 62
12 Overall hight (B) mm 63
13 Weight kg 64
14 Flow rate a.c m³/h 65
15 66 Connection type
16 67 Switching state
17 68 Meter factor 1/m³
18 69
19 70
20 71
21 72
22 73 Connection type
23 Design temperature °C 74 Switching state
24 75
25 76
26 77 Connection type
27 78 Switching state
28 79
29 80
30 81
31 82
32 83
33 84
34 85
Transcucer material (wetted) Titanium
TRANSDUCER
Pressure tapping 1/4" NPTF DO3 Clamp 81/82(RS485) SICK_MODBUS_ASCII
Enclosure rating IP 67 NAMUR (8,2V / 0,8...6,6mA)
Painting
Gre
y
white (RAL9002)/
g
re
y
(RAL7012) sta
normally open
Design pressure
Material test certificate 3.1 EN10204 DO2 Clamp 41/42 (Status) Maintenance required
Exchangeabil. under press. No NAMUR (8,2V / 0,8...6,6mA)
-20 ... 150 normally open
Material Carbon Steel (1.1120/WCC) DO1 Clamp 51/52 (Pulse) Volume a.c.
Flange face RFSD-Raised Face-Stock Finished MOD Clamp 33/34 (RS 485) SICK_MODBUS_ASCII
Flange standard ANSI B16.5
Flange/pressure rating Class 600
Typical meas. uncertainty +/- 0,2% of MV 0,1 ,, 1 Qmax NAMUR (8,2V / 0,8...6,6mA)
Repeatability < 0,1% 10100
50 ... 4000 DO0/AO0 Clamp 31/32 (Pulse) Volume a.c., no pulses when data invalid
Path design 4 Path parallel (4P)
600 Unit system Metric
330
SIGNAL PROCESSING UNIT - CONFIGURATION
Schedule 80 Display LCD SICK
750 LCD language English
Order no. SPU housing material Aluminium (-20°C)
METER BODY
0 ... 40
TAG no. (32 chars)
TAG-No. (max.8 char)
Article Ex approval. CSA Group D T4, 1/2 NPT
Nominal size 10 Inch/DN250 Cable entry 3 x 1/2 NPT
Meter type Flow meter Enclosure rating IP 67
OVERVIEW SIGNAL PROCESSING UNIT
Power supply / power consumption
Instrument Data Sheet for Ultrasonic Gas Flow Meter
TYPE CODE
FL600-4P3D10CL0600SC0080RF0N-S2-1DC1N1Y