Commissioning
54 FLOWSIC600 · Operating Instructions · 8010458 V2.0 · © SICK MAIHAK GmbH
4.5.1 Disconnecting from the Meter and Closing the Session
When you disconnect from the meter, a session is stored in the MEPAFLOW600 CBM meter
database. It contains the following data:
● a complete parameter set from the meter at disconnection
● all parameter changes made during Field setup (entries can be viewed in the Meter
Explorer)
● all logbook data downloaded on page 7 of the Field setup
● the Maintenance Report created on page 8 of the Field setup
You can later access this data with the “Meter Explorer”, even when you are not directly
connected to the meter.
To disconnect from the meter and to close the session, proceed as follows:
b
Go to the “Connect / Disconnect“ page by chosing “File / Connect/Disconnect“ from
the menu.
b
Click the “Disconnect“ button. The “Session description“ window opens.
b
Describe the activies you carried out during the session (e.g. “Field Setup“).
b
Click the “OK“ button.