Maintenance
66 FLOWSIC600 · Operating Instructions · 8010458 V2.0 · © SICK MAIHAK GmbH
5.2.4 Battery Lifetime / Capacity
The Real Time Clock (RTC) of the FLOWSIC600 is buffered by a battery with a guaranteed
life span of 10 years. The remaining battery capacity can be viewed on the LCD in the first
menu level (see Technical Information).
Figure 29 Display of remaining battery capacity on the LCD display
Because the FLOWSIC600 has no regular maintenance cycle, after 8.5 years, a message
will be generated automatically, which forces the operator to change the battery. See
→
pg.76, 6.2.3 for troubleshooting.
Battery
Charge 100%