Appendix
Figure 38 Common key code (for short description of meter design, indicated on Type Plate and Instrument
Data Sheet**)
** The Instrument Data Sheet is included in the Manufacturer Data Report (MDR).
Group
7 8 10 12 13 14 15
FL600- - -
METER BODY
Path configuration
1-Path 1 P
2-Path 2 P
4-Path 4 P
1+1-Path redundant 1 R
2+2-Path redundant 2 R
4+4-Path (Qatro) 4 R
4+1-Path (2plex) 5 C
2-Path crossed 2 X
4-Path crossed 4 X
Overall length
2D (at meters >24") 2 D
3D (standard length) 3 D
5D 5 D
Shortened Meter body S D
Other size X D
Nominal size
2" / DN 50 0 2
3" / DN 80 0 3
4" / DN 100 0 4
6" / DN 150 0 6
8" / DN 200 0 8
10" / DN 250 1 0
12" / DN 300 1 2
16" / DN 400 1 6
Other size X X
Connection flange type
ANSI CLASS 150 C L0150
ANSI CLASS 300 C L0300
ANSI CLASS 600 C L0600
ANSI CLASS ??? C L XXXX
DIN/ISO PN16 P N 0016
DIN/ISO PN 64 P N 0064
DIN/ISO PN 100 P N 0100
DIN/ISO PN ??? P N XXXX
Inner diameter
Schedule 40 (ANSI) SC0040
Schedule 80 (ANSI) SC0080
Schedule ??? (ANSI) SCXXXX
Specified in [mm] (DIN) X X X . X X
Flange type / sealing face
Raised Face (ANSI B16.5) RF
Ring Type Joint (ANSI B16.5) RJ
Glatt Form C (DIN 2526) GC
Glatt Form E (DIN 2526) GE
Form B1 (EN 1092-1) B1
Form B2 (EN 1092-1) B2
Special design XX
Material
Carbon Steel (1.1120 / ASTM A216 Gr. WCC ) 0
Stainless steel (1.4408 / ASTM A351 Gr. CF8M) 1
LT-CS (1.6220 / ASTM A352 Gr. LCC) 2
Duplex (1.4470 / ASTM A995 Gr. 4A / UNS J92205) 3
Superduplex (1.4469 / ASTM A995 Gr. 5A) 4
Superaustenit (1.4557 / ASTM A351 Gr. CK-3MCuN) 5
Connection for Extraction Tool
Yes Y
No N
9
ULTRASONIC TRANSDUCER
(Will be selected by SICK on the basis of the technical data ) _ _
SIGNAL PROCESSING UNIT
Ex-proof-design
CSA Group D T4 1
CSA Group B, C, D T4 2
ATEX IIA T4, M20x1.5 3
ATEX IIC T4, M20x1.5 4
ATEX IIA T4, 1/2 NPT 5
ATEX IIC T4, 1/2 NPT 6
11
Power supply
12 ... 24V DC DC
Data outputs
Hardware variant 1 (4 digital outputs) 1
Hardware variant 2 (1 analog current output and 3 digital outputs) 2
Hardware variant 3 (with integrated volume corrector, p- and T-transmitters internally power supplied) 3
Hardware variant 4 (1 analog current output and 2 RS485) 4
Hardware variant 5 (with integrated EVC, p- and T-transmitters externally power supplied, I/O board with DSP) 5
Hardware variant 6 (with integrated EVC, p- and T-transmitters internally power supplied, I/O board with DSP) 6
Hardwarevariante 7 (same as hardware variant 1, but with LowPressureAnalogBoard) 7
Hardwarevariante 8 (same as hardware variant 2, but with LowPressureAnalogBoard) 8
Hardwarevariante 9 (same as hardware variant 4, but with LowPressureAnalogBoard) 9
Hardware variant A (same as hardware variant 5, but with LowPressureAnalogBoard) A
Hardware variant B (same as hardware variant 6, but with LowPressureAnalogBoard) B
HART-Protocol (By selection of hardware variant 2 and 8 only)
Yes Y
No N
Front panel
LED SICK 0
LCD SICK 1
Custody Transfer design
Yes Y
No N
3
4
1156123 4
2
9
Key code
1
15
14
13
12
5
6
8
10
7
Rev. 1.8