EasyManuals Logo

SICK LFP CUBIC User Manual

SICK LFP CUBIC
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
OPERATING INSTRUCTIONS | LFP CUBIC 8019918/ZJA6 / 2017-07-20 | SICK AG
Subject to change without notice
34
8 OPERATION
8.2.6 N/O output with error signal
Application
If there is an error message at the LFP, this can be transferred using a switching contact.
Conguration
1. Congure the Qx switching output as normally open.
Set the parameter in the QxMENU-OUx menu to Qx_Eno.
2. Select the electrical property (NPN/PNP/DRV (push/pull)).
Select the parameter in the QxMENU-TYPx menu.
The following rules apply:
Qx-PNP = Switching output in PNP circuit
Qx-NPN = Switching output in NPN circuit
Qx-Drv = Switching output in push/pull function
8.2.7 N/C output with error signal
Application
If there is an error message at the LFP, this can be transferred using a switching contact.
Conguration
1. Congure the Qx switching output as normally closed.
Set the parameter in the QxMENU-OUx menu to Qx_Enc.
2. Select the electrical property (NPN/PNP/DRV (push/pull)).
Select the parameter in the QxMENU-TYPx menu.
The following rules apply:
Qx-PNP = Switching output in PNP circuit
Qx-NPN = Switching output in NPN circuit
Qx-Drv = Switching output in push/pull function

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK LFP CUBIC and is the answer not in the manual?

SICK LFP CUBIC Specifications

General IconGeneral
BrandSICK
ModelLFP CUBIC
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals