OPERATING INSTRUCTIONS | LFP CUBIC 8019918/ZJA6 / 2017-07-20 | SICK AG
Subject to change without notice
34
8 OPERATION
8.2.6 N/O output with error signal
Application
If there is an error message at the LFP, this can be transferred using a switching contact.
Conguration
1. Congure the Qx switching output as normally open.
Set the parameter in the QxMENU-OUx menu to Qx_Eno.
2. Select the electrical property (NPN/PNP/DRV (push/pull)).
Select the parameter in the QxMENU-TYPx menu.
The following rules apply:
Qx-PNP = Switching output in PNP circuit
Qx-NPN = Switching output in NPN circuit
Qx-Drv = Switching output in push/pull function
8.2.7 N/C output with error signal
Application
If there is an error message at the LFP, this can be transferred using a switching contact.
Conguration
1. Congure the Qx switching output as normally closed.
Set the parameter in the QxMENU-OUx menu to Qx_Enc.
2. Select the electrical property (NPN/PNP/DRV (push/pull)).
Select the parameter in the QxMENU-TYPx menu.
The following rules apply:
Qx-PNP = Switching output in PNP circuit
Qx-NPN = Switching output in NPN circuit
Qx-Drv = Switching output in push/pull function