10 Technical data
10.1 MAX Analog/PWM
Table 40: Technical data – MAX48 Analog / PWM
Performance
Measurand Position
Measuring range MAX48: 0050 … 2,500 mm (in 1 mm steps)
MAX30: 0050 ... 1,500 mm (in 1 mm steps)
Unusable measuring range:
Null zone (zero point) MAX48: 30.0 mm
MAX30: 19.5 mm
Damping (end point) 30.0 mm/ 36.0 mm/ 63.0 mm (depending on type)
Power-up delay < 250 ms
Measuring frequency (internal) 2 ms
Setpoint tolerance
Zero and end point of the usable piston stroke
≤ 1.0 mm
Resolution 0.1 mm typical (noise-free)
Hysteresis ± 0.1 mm
Linearity:
Measuring ranges 50 ... 500 mm F.S. typically ± 0.25 mm
Measuring ranges 501 ... 2,500 mm F.S. typically ± 0.04%
Temperature drift (warm-up phase) max. ± 0.25 mm
Analog interface
Electrical interface Analog
Voltage signal 0.25 … 4.75 VDC
0.50 … 4.50 VDC
0.50 … 9.50 VDC
1.00 … 9.00 VDC
Current signal 4 … 20 mA
PWM interface
Pulse width 05 … 95%
10 … 90%
15 … 85%
20 … 80%
25 … 75%
Pulse rate 250 Hz
300 Hz
400 Hz
500 Hz
Electrical connection
M12 male connector 4-pin, wire length
060 … 240 mm (depending on type)
3-wire cable 3 x 0.32 mm² (AWG22),
stripped 300 … 10,000 mm (depending on type)
Electrical data
Supply voltage 12 VDC (8 ... 16 VDC)
24 VDC (8 ... 30 VDC)
TECHNICAL DATA 10