7SR210 & 7SR220 Description of Operation
Unrestricted Page 12 of 94 ©2018 Siemens Protection Devices Limited
Table 1.5-2 Ordering Information – 7SR22 Directional Overcurrent
Product description Variants Order No.
7 S R 2 2 0 - 2 A - 0 A 0
Protection Product Family
Overcurrent - Directional
2
Relay Type
0
Case, I/O and Fascia
1)
E6 case, 5 CT, 4 VT, 3 Binary Inputs, 6 Binary Outputs, 8 LEDs
2
C
E8 case, 5 CT, 4 VT, 13 Binary Inputs, 14 Binary Outputs, 16 LEDs
3
E8 case, 5 CT, 4 VT, 13 Binary Inputs, 14 Binary Outputs, 8 LEDs + 6 keys
4
E12 case, 5 CT, 4 VT, 33 Binary Inputs / 14 Binary Outputs, 32 LEDs
5
E12 case, 5 CT, 4 VT, 33 Binary Inputs / 14 Binary Outputs, 16 LEDs, 12 keys
6
Measuring input
1 A or 5 A, 40 V to 160 V, 50 Hz or 60 Hz
2
Auxiliary voltage
PSU Rated: 30 to 220V DC. Binary Input threshold 19V DC (Rated: 24-250V DC)
A
PSU Rated: 30 to 220V DC. Binary Input threshold 88V DC (Rated: 110-250V DC)
B
PSU Rated: 24-250V DC / 100-230V AC. Binary Input threshold 19V DC (Rated: 24-250V DC)
M
PSU Rated: 24-250V DC / 100-230V AC. Binary Input threshold 88V DC (Rated: 110-250V DC)
N
Spare
A
Communication Interface
Standard version - included in all models, USB front port, RS485 rear port
1
Standard version - plus additional rear F/O ST connectors (x2) and IRIG-B
2
Standard version - plus additional rear RS485 and IRIG-B
3
Standard version - plus additional rear RS232 and IRIG-B
4
Standard version - plus additional rear Electrical Ethernet RJ45 (x2)
7
7
Standard version - plus additional rear Optical Ethernet Duplex (x2)
8
7
Protocol
IEC 60870-5-103 and Modbus RTU (user selectable)
1
IEC 60870-5-103 and Modbus RTU and DNP 3.0 (user selectable)
2
IEC 60870-5-103 and Modbus RTU and DNP 3.0 (user selectable) and IEC61850
7-8
7
Spare
0
Protection Function Packages
Standard version - included in all models
C
21FL Fault Locator
21LB Load Blinder
27/59
1)
Under/overvoltage
32 Power
32S Sensitive Power
37 Undercurrent
37G
1)
Ground Undercurrent
37SEF
1)
SEF Undercurrent
46BC Broken conductor/load unbalance
46NPS Negative phase sequence overcurrent
47
1)
Negative phase sequence voltage
49 Thermal overload
50 Instantaneous phase fault overcurrent
50BF Circuit breaker fail
50G/50N Instantaneous earth fault
50 AFD Arc Flash Detector
51V Voltage dependent overcurrent
55 Power factor
59N Neutral voltage displacement
60CTS CT supervision
60CTS-I CT supervision
60VTS VT supervision
64H High impedance REF
67/50 Directional instantaneous phase fault overcurrent
67/50G
67/50N
Directional instantaneous earth fault/SEF
67/51 Directional time delayed phase fault overcurrent
67/51G
67/51N
Directional tIme delayed earth fault/SEF
74TC/CCS Trip & close circuit supervision
81 Under/overfrequency
81HBL2 Inrush Detector
81HBL5 Overfluxing
86
Lockout
Cold load pickup
Programmable logic
CB Control
Standard version - plus
D
79
Autoreclose
Standard version - plus
E
79 + 25
Additional Functionality
No additional functionality
A
Spare
0
Export Data
HS: 8536900
ECCN: N
AL: N
1)
5CT is configured as 3PF + EF/SEF + EF/SEF (user selectable setting).
Autoreclose + Check Sync