7SR220 Settings Guide
Unrestricted ©2018 Siemens Protection Devices Limited Page 79 of 107
Description Range Default
50N-3
50N-3 INST/DTL derived Earth Fault operated
Combination of ( BO1, BO2, BO3,
BO4, BO5, BO6, BO7, BO8, BO9,
BO10, BO11, BO12, BO13, BO14,
L1, L2, L3, L4, L5, L6, L7, L8, L9,
L10, L11, L12, L13, L14, V1, V2,
V3, V4, V5, V6, V7, V8, V9, V10,
V11, V12, V13, V14, V15, V16 )
L4
50N-4
50N-4 INST/DTL derived Earth Fault operated
Combination of ( BO1, BO2, BO3,
BO4, BO5, BO6, BO7, BO8, BO9,
BO10, BO11, BO12, BO13, BO14,
L1, L2, L3, L4, L5, L6, L7, L8, L9,
L10, L11, L12, L13, L14, V1, V2,
V3, V4, V5, V6, V7, V8, V9, V10,
V11, V12, V13, V14, V15, V16 )
L4
51G-1
51G-1 IDMTL/DTL measured Earth Fault operated
Combination of ( BO1, BO2, BO3,
BO4, BO5, BO6, BO7, BO8, BO9,
BO10, BO11, BO12, BO13, BO14,
L1, L2, L3, L4, L5, L6, L7, L8, L9,
L10, L11, L12, L13, L14, V1, V2,
V3, V4, V5, V6, V7, V8, V9, V10,
V11, V12, V13, V14, V15, V16 )
L4
51G-2
51G-2 IDMTL/DTL measured Earth Fault operated
Combination of ( BO1, BO2, BO3,
BO4, BO5, BO6, BO7, BO8, BO9,
BO10, BO11, BO12, BO13, BO14,
L1, L2, L3, L4, L5, L6, L7, L8, L9,
L10, L11, L12, L13, L14, V1, V2,
V3, V4, V5, V6, V7, V8, V9, V10,
V11, V12, V13, V14, V15, V16 )
L4
51G-3
51G-3 IDMTL/DTL measured Earth Fault operated
Combination of ( BO1, BO2, BO3,
BO4, BO5, BO6, BO7, BO8, BO9,
BO10, BO11, BO12, BO13, BO14,
L1, L2, L3, L4, L5, L6, L7, L8, L9,
L10, L11, L12, L13, L14, V1, V2,
V3, V4, V5, V6, V7, V8, V9, V10,
V11, V12, V13, V14, V15, V16 )
L4
51G-4
51G-4 IDMTL/DTL measured Earth Fault operated
Combination of ( BO1, BO2, BO3,
BO4, BO5, BO6, BO7, BO8, BO9,
BO10, BO11, BO12, BO13, BO14,
L1, L2, L3, L4, L5, L6, L7, L8, L9,
L10, L11, L12, L13, L14, V1, V2,
V3, V4, V5, V6, V7, V8, V9, V10,
V11, V12, V13, V14, V15, V16 )
L4
50G-1
50G-1 INST/DTL measured Earth Fault operated
Combination of ( BO1, BO2, BO3,
BO4, BO5, BO6, BO7, BO8, BO9,
BO10, BO11, BO12, BO13, BO14,
L1, L2, L3, L4, L5, L6, L7, L8, L9,
L10, L11, L12, L13, L14, V1, V2,
V3, V4, V5, V6, V7, V8, V9, V10,
V11, V12, V13, V14, V15, V16 )
L4
50G-2
50G-2 INST/DTL measured Earth Fault operated
Combination of ( BO1, BO2, BO3,
BO4, BO5, BO6, BO7, BO8, BO9,
BO10, BO11, BO12, BO13, BO14,
L1, L2, L3, L4, L5, L6, L7, L8, L9,
L10, L11, L12, L13, L14, V1, V2,
V3, V4, V5, V6, V7, V8, V9, V10,
V11, V12, V13, V14, V15, V16 )
L4
50G-3
50G-3 INST/DTL measured Earth Fault operated
Combination of ( BO1, BO2, BO3,
BO4, BO5, BO6, BO7, BO8, BO9,
BO10, BO11, BO12, BO13, BO14,
L1, L2, L3, L4, L5, L6, L7, L8, L9,
L10, L11, L12, L13, L14, V1, V2,
V3, V4, V5, V6, V7, V8, V9, V10,
V11, V12, V13, V14, V15, V16 )
L4