Creating and checking the safety printout of the PLC
Create the safety printout by right-clicking on "Safety administration" and selecting "Print" in the
shortcut menu.
All the relevant data is listed in the safety printout.
Note
Error-free hardware and software transmission
Error-free HW and SW transmission is the prerequisite for the creation of the safety printout for
acceptance purposes. Only then is it assured that all consistency checks have been performed
and therefore the safety printout created for a consistent project.
Example of a safety printout
Here is an example of an NCU 730.3 PN with SINAMICS Integrated standard configuration (6
drive objects).
In the SINAMICS Integrated overview table, the PROFIsafe addresses of the individual drive
objects are listed under "F-destination address".
Figure 10-13 PROFIsafe address in the safety printout
In the tables below, further details on the PROFIsafe telegrams of the individual drive objects
are listed.
Checking the PROFIsafe address in the safety printout
Compare the PROFIsafe address with the value of the drive parameter p9610 in
SINUMERIK Operate.
Compare this PROFIsafe address with the values of all other nodes and ensure uniqueness.
Safety configuration
10.8 Configuring Safety Integrated plus (F-PLC)
SINUMERIK STEP 7 Toolbox V15.1
Configuration Manual, 12/2018, A5E46279635B AA 209

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals