Data blocks / error lists
C.1 Content of the channel DB
FM 352 electronic cam controller
184 Operating Instructions, 05/2011, A5E01071724-03
Address Name Type Initial value Comment
Relative address
+0.0 CAM_NO BYTE B#16#0 Number of the cam to modify
+1.0 C_EFFDIR BOOL FALSE 1 = change the effective direction
+1.1 C_CBEGIN BOOL FALSE 1 = change the cam start to the value CBEGIN
(new cam start)
+1.2 C_CEND BOOL FALSE 1 = change the cam end / activation time to
the value CEND (new cam end)
+1.3 C_LTIME BOOL FALSE 1 = change the lead time to the LTIME value
(new lead time)
+1.4 CAM_OFF BOOL FALSE 1 = deactivate the cam during the cam change
+1.5 EFFDIR_P BOOL FALSE 1 = new effective direction positive (plus)
+1.6 EFFDIR_M BOOL FALSE 1 = new effective direction negative (minus)
+2.0 CBEGIN DINT L#0 New cam start
+6.0 CEND DINT L#0 New cam end / new activation time
+10.0 LTIME INT 0 New lead time