Machine and cam data
9.12 Quantity framework and track data
FM 352 electronic cam controller
94 Operating Instructions, 05/2011, A5E01071724-03
9.12 Quantity framework and track data
Number of cams
The number of cams available determines the cam cycle time and the maximum number of
assignable cams.
Number of cams Cam cycle time
16 cams 20.48 µs
32 cams 40.96 µs
64 cams 81.92 µs
128 cams 163.84 µs
Number of cams in the parameter DB
Address Name Type Start value Comment
76.0
C_QTY
DINT
UDT3: L#0
UDT4: L#1
UDT5: L#2
UDT6: L#3
Number of cams:
0 = max. 16 cams
1 = max. 32 cams
2 = max. 64 cams
3 = max. 128 cams
Track data in the parameter DB
Activation of track outputs
Address Name Type Start value Comment
90.0 TRACK_OUT WORD W#16#0 Activation of track outputs
Range:
0 = cam controller
1 = CPU
Bit number = track number
Bits 13 to 15 must be 0.
The machine data "activation of track outputs" defines how the track signals of tracks 0 to 12 are
activated. Tracks can be activated by:
The cam controller: Track signals are activated and deactivated by the FM 352 cam processing
functions.
CPU: The track signals represent the corresponding values of the track enables in the channel
DB.
This allows the explicit activation of track outputs in the user program.