Programming the FM 352
7.9 Technical data
FM 352 electronic cam controller
Operating Instructions, 05/2011, A5E01071724-03
55
7.9 Technical data
Overview
The table below provides an overview of the technical specifications for the FM 352 blocks.
Table 7- 2 Technical specifications for FM 352 blocks
No. Block name Version Allocation
in load
memory
(bytes)
Allocation in
work
memory
(bytes)
Allocation in
local data
area
(bytes)
MC7 code /
data
(bytes)
System functions
called
FC 0 FC CAM_INIT 1.0 192 138 2 102
FB 1 FB CAM_CTRL 1.0 6940 5768 28 5768 SFB 53: WR_REC,
SFB 52: RD_REC
FB 2 FB CAM_DIAG 1.0 2122 1874 36 1838 SFB 52: RD_REC
Channel DB - 1102 464 - 428
Parameter DB 16
Parameter DB 32
Parameter DB 64
Parameter DB 128
-
-
-
-
616
808
1192
1960
336
528
912
1680
-
-
-
-
300
492
876
1644
Diagnostic DB - 532 368 - 332
Module cycle
The module updates the checkback data (except in the pulses measuring system) every
4 ms.
In the pulses measuring system, the data for the actual position value and track signals are
available after 1 ms.