EasyManua.ls Logo

Siemens S7-300 - Data Blocks; Templates for Data Blocks; Channel DB

Siemens S7-300
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming the FM 352
7.5 Data blocks
FM 352 electronic cam controller
Operating Instructions, 05/2011, A5E01071724-03
49
7.5 Data blocks
7.5.1 Templates for data blocks
The included FM352LIB library contains a block template (UDT) for the different variants of
the machine data DB. Based on this UDT, you can create data blocks with user-specific
numbers and names. You generate channel and diagnostic DBs as instances of FB 1 and
FB 2.
7.5.2 Channel DB
Task
The channel DB forms the data interface between the user program and the FM 352
electronic cam controller. It contains and accepts all data required for controlling and
operating the module.
Configuration
The channel DB is divided into various areas:
Channel DB
Address* /version switch
Control signals
Checkback signals
Function switches
Trigger bits for write jobs
Trigger bits for read jobs
Done bits
Error bits
Job management for functions
Data for jobs
* You can enter the address in the parameter assignment interface.

Table of Contents

Other manuals for Siemens S7-300

Related product manuals