6.23.15 Gross process weight 1 [grossProcessWeight1], Net process weight 1
[netProcessWeight1], Tare process weight [tareProcessWeight]
These are the gross, net and tare weights in high-resolution process form.
6.23.16 Gross weight [grossWeight], Net weight [netWeight], Tare weight [tareWeight]
These are the gross, net and tare weights after rounding and filtering defined in data record 3.
6.23.17 Gross/net weight x10 [netWeightX10]
This is the gross and net weight after rounding according to settings in DR03 and a resolution
raised by a factor of 10.
6.23.18 Gross process weight 2 [grossProcessWeight2], Net process weight 2
[netProcessWeight2]
These are the high-resolution, internal process values of the gross and net weight after filtering
according to filters 1 and 2 (DR03).
6.23.19 Last net process weight [lastNetProcessWeight], Last net weight [lastNetWeight]
The parameters show the last dosed net process weight or net weight.
6.23.20 Totalizer 1 [totalizer1] and Totalizer 2 [totalizer2]
Two totalizer memories that you reset separately using a command. Delete totalizer 1:
Command code: 651; Delete totalizer 2: Command code: 652. In NAWI and CWI modes, the
dosed weight is added to the totalizers after the tolerance check. In weighing operating mode
GFI, the actual weight determined by the tolerance check in checked cycles is cumulated. For
cycles without tolerance check, the set point set in DR20 is included in the calculated totalizers.
In DTI mode, totalizer 1 represents the legal-for-trade totalizer.
6.23.21 Youngest protocol ID [youngestLogId]
After a successful logging, the "Youngest protocol-ID" parameter is incremented and
represents the last protocol ID to be created.
Parameter assignment/addressing
6.23 DR30 Read out process state
Technology module TM SIWAREX WP351 HF
106 Operating Instructions, 01/2020, A5E47521010-AA

Table of Contents

Other manuals for Siemens SIMATIC ET 200SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200SP and is the answer not in the manual?

Siemens SIMATIC ET 200SP Specifications

General IconGeneral
System TypeDistributed I/O System
MountingDIN Rail
Communication ProtocolPROFINET, PROFIBUS
IP RatingIP20
CategoryI/O Systems
Supply Voltage24 V DC
ModularityYes
Hot SwappingYes
Storage Temperature-40°C to +70°C
Digital InputsYes
Digital OutputsYes
Analog InputsYes
Analog OutputsYes
Communication InterfacePROFINET, PROFIBUS
Number of ModulesUp to 64
Relative Humidity5 to 95% (non-condensing)
Operating Temperature-25°C to +60°C