6. Write DR03 by entering the command code 4003 for the "code" parameter in the
"Command1" command mailbox.
7. Set the associated command trigger "trigger" to "true".
8. Evaluate the associated status bits:
Command finished without error. [finishedOk] is "true".
The new calibration weight is now present in the electronic weighing system and is used.
9. Disable service mode by entering command code 2 for the "code" parameter.
10.Set the associated command trigger "trigger" to "true".
6.2.4 Cyclic data exchange via "cyclicIoData"
The interface DB of the FB makes the "cyclicIoData" structure available. All parameters in this
structure are updated cyclically by the electronic weighing system to the SIMATIC controller. All
entered parameter values within the "cyclicIoData" structure are used directly without reading
or writing DRs.
The following parameters are available for use within the "cyclicIoData" structure on the factory
side:
Parameter assignment/addressing
6.2 TIA Portal user program
Technology module TM SIWAREX WP351 HF
46 Operating Instructions, 01/2020, A5E47521010-AA

Table of Contents

Other manuals for Siemens SIMATIC ET 200SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200SP and is the answer not in the manual?

Siemens SIMATIC ET 200SP Specifications

General IconGeneral
System TypeDistributed I/O System
MountingDIN Rail
Communication ProtocolPROFINET, PROFIBUS
IP RatingIP20
CategoryI/O Systems
Supply Voltage24 V DC
ModularityYes
Hot SwappingYes
Storage Temperature-40°C to +70°C
Digital InputsYes
Digital OutputsYes
Analog InputsYes
Analog OutputsYes
Communication InterfacePROFINET, PROFIBUS
Number of ModulesUp to 64
Relative Humidity5 to 95% (non-condensing)
Operating Temperature-25°C to +60°C