EasyManuals Logo

Siemens SIMATIC ET 200SP Operating Instructions

Siemens SIMATIC ET 200SP
166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #111 background imageLoading...
Page #111 background image
6.30 DR47 Read out logbook content
Changes to the used software version of SecureDisplay of the legal-for-trade main display
[HMI] and changes to the firmware of the electronic weighing system are recorded in the
logbook.
Scrolling in the logbook is possible using commands 881 to 883.
Legal-for-trade reading of the logbook is carried out using the SecureDisplay legal-for-trade
main display. Non-legal-for-trade reading is carried out using DR47.
6.31 Commands
6.31.1 Overview
The commands for the electronic weighing system described here can be transmitted by the
following interfaces:
From the SIMATIC HMI via the SIMATIC controller to the electronic weighing system
From the SIMATIC HMI directly to the electronic weighing system via Modbus
From the web server directly to the electronic weighing system
Via the digital inputs after corresponding assignment in data record DR07
If an issued command is not accepted by the electronic weighing system, the cause of the
rejection is always substantiated with a corresponding data/operating error.
Detailed descriptions of the commands can be found in the following tables:
→ Table 6-3 Service commands (Page 112)
→ Table 6-4 Protocol commands, statistics, logbook (Page 113)
→ Table 6-5 Trace commands (Page 113)
→ Table 6-6 Totalization commands (Page 114)
→ Table 6-7 Display changeover for DR34 and SecureDisplay (Page 114)
→ Table 6-8 Scale commands (Page 115)
→ Table 6-9 Weighing commands (Page 116)
See also
Commands (Page 112)
Parameter assignment/addressing
6.31 Commands
Technology module TM SIWAREX WP351 HF
Operating Instructions, 01/2020, A5E47521010-AA 111

Table of Contents

Other manuals for Siemens SIMATIC ET 200SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200SP and is the answer not in the manual?

Siemens SIMATIC ET 200SP Specifications

General IconGeneral
System TypeDistributed I/O System
MountingDIN Rail
Communication ProtocolPROFINET, PROFIBUS
IP RatingIP20
CategoryI/O Systems
Supply Voltage24 V DC
ModularityYes
Hot SwappingYes
Storage Temperature-40°C to +70°C
Digital InputsYes
Digital OutputsYes
Analog InputsYes
Analog OutputsYes
Communication InterfacePROFINET, PROFIBUS
Number of ModulesUp to 64
Relative Humidity5 to 95% (non-condensing)
Operating Temperature-25°C to +60°C