Mounting
5.5 Mounting with external ring light
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
113
Proceed as follows to mount the SIMATIC MV540 optical reader with an external ring light:
1. Remove the protective foil from the reader.
2. When using an E-focus lens: Insert the straight connector of the lens cable into the interface
of the reader (a).
3. Screw the desired lens into the lens mount of the reader.
Ensure the correct alignment of the lens so that the interface is close to the
cutout/interface (a). If needed, unscrew the lens slightly. If needed, align the lens using
the knurled nut/spring/counter ring.
4. When using an E-focus lens: Use the lens cable to connect the E-focus lens to the reader.
Insert the angled connector of the lens cable into the interface of the lens and the straight
connector into the interface of the reader. Ensure that the cable does not become twisted.
5. Insert the micro SD adapter into the reader interface provided.
If needed, insert a micro SD card into the adapter
6. Screw the protective lens barrel (article number 6GF3540-8AC11) onto the reader.
7. Mount the ring light holder on the reader with the 4 screws (1-2 Nm) that are supplied.
8. Mount the external ring light to the ring light holder (1-2 Nm) with the 2 supplied fastening
screws.
9. Mount the reader on a suitable mounting fixture or holder (4x M4, 1-2 Nm).
Use the mounting plate for SIMATIC MV500 or a mounting device with matching holes.
Note that the reader has two different drilling templates (50 x 60/57 x 57).
10.Select a suitable location to install the device.

Table of Contents