Table 11- 3 Technical specifications of the built-in ring lights for SIMATIC MV500
6GF3540-8DAxx
Product type designation
Built-in ring light for SIMATIC MV500
Optical data
Lighting distance (max.)
8DA11: 0.8 m
8DA12: 3.0 m
8DA13: 1.5 m
8DA33: 1.5 m
8DA41: 0.8 m
8DA42: 3.0 m
Light color / wavelength
(relative luminosity 0.2 ... 1.0)
8DA11: Red / 625 nm
8DA12: Red / 625 nm
8DA13: Red / 625 nm
8DA33: White / 6500 K
8DA41: IR / 850 nm
8DA42: IR / 850 nm
Flash mode
Duty cycle 8%
Max. exposure time 10 ms
Permitted ambient conditions
Ambient temperature
During operation
0 … +50 °C
During transportation and storage
-20 … +70 °C
Relative humidity (max.)
95%
Design, dimensions and weight
Dimensions ( × H)
54 × 54 mm
Weight
Approx. 40 g
Standards, specifications, approvals
MTBF
8DA11: 283 years
8DA12: 150 years
8DA13: 150 years
8DA33: 151 years
8DA41: 289 years
8DA42: 155 years