Image processing
3.2 Code verification
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
49
Figure 3-6 Incorrect overall geometry of the marking
Figure 3-7 Damaged surface of the marking or part
Figure 3-8 Very little or non-uniform contrast in the marking
3.2.3.4 Verification standards supported
The optical readers without a verification license support the following verification standards:
Uncalibrated verification according to ISO/IEC 29158 and ISO/IEC 16022 for data matrix
Uncalibrated verification according to ISO/IEC 15416 for various 1D bar codes
The optical readers with a "Veri-Genius" license also support the following verification
standards:
Data matrix verification to ISO/IEC 15415:2004
Data matrix verification to AS9132 Rev A:2005 (previously IAQG) for dot peen markings
Siemens DPM
Data matrix verification to ISO/IEC 29158:2011
Barcode verification to ISO/IEC 15416:2000 (previously ANSI X3.182-1990)
Note
Veri
-Genius license
For productive use, you require a Veri-Genius license (article number "6GF3400-0SL02").