1.2 Product characteristics
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
19
Up to 150 codes can be read per image acquisition (SIMATIC MV500 U/X)
Code verification according to ISO/IEC 16022
Integrated communications interfaces
Ethernet 10/100/1000 Mbps for TCP/IP and PROFINET IO depending on the device version
1 trigger input and 1 flash output
Response time of the trigger input: 50-70 us
Jitter (fluctuation of response time): max. 40 ns
Incoming triggers during a running image acquisition do not interrupt it. Triggers that are
incoming during an image acquisition are handled as NOK processing procedures and
included in the processing statistics.
Communication module interface
RS232 with TxD and RxD
2 configurable digital inputs/outputs
Extended communication via communication modules
ASM 456 for PROFIBUS DP/V1
RF120C, RF170C, RF180C and RF185C/RF186C/RF188C for PROFINET
Power over Ethernet
Integrate power supply via Ethernet cable (PoE)
Robust construction, suitable for industry
Degree of protection IP67
With the protective lens barrel screwed on and all interfaces closed by cable connections or
protective caps.
Protective lens barrel
Barrel with filter thread