Process interfacing via an automation system (PLC, PC)
9.10 Example programs
SIMATIC MV500
218 Operating Instructions, 03/2021, C79000-G8976-C494-05
Please note that there is only one common setting for MMI transfer and the internal error
image memory. It is not possible to make separate and therefore different settings here.
Requirements
.NET Framework v4.0 must be installed to run the demo program.
The PC must be connected with the optical reader over the Ethernet interface.
The Ethernet interface involved and the PC must be located in the same subnet.
Settings in WBM
Make the following settings in the WBM:
"Settings > Communication > Interfaces > Archiving/MMI" menu:
Enter the IP address and the port of the PC on which you want to archive the diagnostic
information.
"Settings > Communication > Use > Diagnostics transfer" menu:
Select from the drop-down lists which data you want to archive: Diagnostics data sets,
diagnostic images or both.