Scope of delivery and ordering data
13.3 Accessories
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
267
External ring lights and flood-
Description Article number
(20 x 20)
• Power supply: 24 V (19 ... 30 V)
• Irradiance: 49 W/m² @ 0.2 m
• Irradiance: 0.5 m - 10.2 W/m²
• Dimensions (L × W × H)
240 × 220 × 22 mm
• Degree of protection IP64
Including connecting cable, 10 m
0
(30 x 20)
• Power supply: 24 V (19 ... 30 V)
• Irradiance: 84 W/m² @ 0.2 m
• Irradiance: 0.5 m - 19.4 W/m²
• Dimensions (L × W × H)
320 × 240 × 22 mm
• Degree of protection IP64
• Including connecting cable, 10 m
0
(40 x 30)
• Power supply: 24 V (19 ... 30 V)
• Irradiance: 94 W/m² @ 0.2 m
• Irradiance: 0.5 m - 27.4 W/m²
• Dimensions (L × W × H)
420 × 340 × 22 mm
• Degree of protection IP64
Including connecting cable, 10 m
0
Table 13- 7 Support for external ring lights/floodlights
Ring light holder for external ring
light
• Dimensions (W × H × D):
96 × 76 × 46 mm
• Screws are supplied.
• Dimensions (W × H × D):
113 × 130 × 132 mm
Table 13- 8 Connecting cable for external ring lights
Adapter cable for external ring
lights
M12, 12-pin
• Power supply via combination interface
M12, 12-pin double-sided
• Length: 25 cm