Glossary
S7-300 Module data
636 Manual, 06/2017, A5E00105505-AJ
Smoothing
STEP 7 parameter for analog input modules. The measured values are smoothed by digital
filtering. Users can select module-specific filter properties, i.e. none, low, medium or high.
The time constant of the digital filter increases in proportion to the degree of smoothing.
STARTUP
STARTUP mode initiates the transition from STOP to RUN mode. STARTUP can be
triggered by setting the → mode selector, by power on, or by an operator action on the
programming device. S7-300 performs a → restart.
Substitution value
Values output by faulty signal output modules to the process, or used to substitute a process
value of a faulty signal input module in the user program.
Users can program the substitute values in STEP 7 (hold last value, substitution value 0 or
1.) Those values must be set at the outputs when the CPU goes into STOP.
System diagnostics
Denotes the detection, evaluation and reporting of error events within the automation
system. Examples of such errors are: program errors, or module failure. System errors may
be indicated by LED displays, or in
STEP 7
.
System Function
A System Function (SFC) is an integral function of the CPU operating system, and can be
called in the STEP 7 user program as required.
Temperature coefficient
STEP 7
parameter for analog input modules, for temperature measurements taken with
resistance thermometers (RTD.) The selected temperature coefficient is specific to the
resistance thermometer being used (to DIN standard.)
Temperature error
Denotes the drift of measured/output values, caused by fluctuation of the ambient
temperature at an analog module. It is defined in % per Kelvin, relative to the rated range of
the analog module.
Temperature error of internal compensation
Only applies to the measurement of thermocouples. Defines the error to add to the actual
temperature error, when "internal comparison" mode is selected. The error is defined either
as a percentile value relative to the physical rated range of the analog module, or as an
absolute value in °C.

Table of Contents

Other manuals for Siemens SIMATIC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC and is the answer not in the manual?

Siemens SIMATIC Specifications

General IconGeneral
Product type designationSIMATIC
CPUVaries by model
MemoryVaries by model
Input/OutputVaries by model
CommunicationVaries by model
Programming LanguageSTEP 7
Operating Temperature0°C to 60°C (varies by model)
Protection ClassIP20
CategoryProgrammable Logic Controller (PLC)

Related product manuals