7.2 Setpoint values for monitoring the bearing temperature
Prior to commissioning
If the machine is equipped with bearing thermometers, set the temperature value for
disconnection on the monitoring equipment before the 󹪝rst machine run.
Table 7-1 Set values for monitoring the bearing temperatures before commissioning
Set value Temperature
Alarm 115°C
Shutting down 120°C
Normal operation
Determine the maximum operating temperature of the bearings T
operation
taking into account the
temperature, bearing load and in󹪞uences of the plant on the motor in °C. Set the values for
shutdown and warning corresponding to the operating temperature T
op
.
Table 7-2 Set values for monitoring the bearing temperatures
Set value Temperature
Alarm T
operation
+ 5K ≤115 °C
Shutting down T
operation
+ 10K ≤120 °C
7.3 Switching on
Measures for start-up
After installation or inspections, the following measures are recommended for normal start-up
of the machines:
Start the machine without a load. To do this, close the circuit breaker and do not switch o󹪜
prematurely. Switching the machine o󹪜 again while it is starting and still running at slow
speed should only be done to the extent necessary, for example for checking the direction of
rotation or for checking in general. Allow the machine to run down before switching it on
again.
Check mechanical operation for noise or vibration at the bearings or end shields.
If the machine is not running smoothly or is emitting abnormal noises, switch it o󹪜, and
determine the cause of the fault as it runs down.
If mechanical operation improves immediately after the machine is switched o󹪜, then the
cause is magnetic or electrical, e.g. voltage imbalance, magnetic imbalance. If mechanical
operation does not improve immediately after switching the machine o󹪜, then the cause is
mechanical, e.g. an imbalance in the electrical machines or in the driven machine,
inadequate alignment of the machine set, operation of the machine with the system
resonating (system = machine + base frame + foundations etc.).
Commissioning
7.3Switching on
1MB..1/2/3/4 - shaft heights 63 ... 355
Operating Instructions, 11/2023, A5E52779900A 99

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS XP 1MB 1 Series and is the answer not in the manual?

Siemens SIMOTICS XP 1MB 1 Series Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS XP 1MB 1 Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals