CAUTION
Risk of injury when touching the fan
There is a risk of injury at machines equipped with a fan cover (e.g. on machines in the textile
industry), as the fan is not completely touch protected.
Do not touch the rotating fan.
Do not put your 󹪝ngers into the larger air discharge openings.
Prevent manual intervention by using suitable measures, e.g. appropriate housings or a
protective grating.
8.1.2 Switching on with the anti-condensation heating active
Excessively high machine temperature when the anti-condensation heating is switched on
If the anti-condensation heating is operated while the machine is running, this can increase the
temperatures inside the machine. Material damage can result.
Switch o󹪜 the anti-condensation heating before switching on the machine.
Only operate anti-condensation heating when the machine is switched o󹪜.
WARNING
Explosion hazard
If the anti-condensation heating is switched on during operation, the temperature class or the
maximum surface temperature of the machine can be exceeded.
In an explosive atmosphere, there is a risk of an explosion. This can result in death, serious
injury or material damage.
Only switch on the anti-condensation heating after the motor has been switched-o󹪜.
Comply with the data stamped on the plate of the anti-condensation heating, if available.
Operation
8.1Safety instructions for operation
1MB..1/2/3/4 - shaft heights 63 ... 355
108 Operating Instructions, 11/2023, A5E52779900A

Table of Contents