EasyManuals Logo

Siemens SIMOTICS XP 1MB 1 Series User Manual

Siemens SIMOTICS XP 1MB 1 Series
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
Operation
8
Comply with the following when carrying out any work on the machine:
Comply with the general safety instructions (Page15).
Comply with the applicable national and sector-speci󹪝c regulations.
When using the motor within the European Union, comply with the speci󹪝cations laid down
in EN50110‑1 regarding safe operation of electrical equipment.
8.1 Safety instructions for operation
Hazardous voltages at the machine
Electrical machines have hazardous voltage levels. Contact with these can result in death,
serious injury or material damage.
Operating the machine on a line supply system with a non-grounded neutral point is only
permissible for short periods of time that occur rarely, e.g. the time leading to a fault being
eliminated. Cable ground fault EN/IEC 60034-1.
Risk of injury due to rotating parts
Rotating parts are dangerous. Touch protection against rotating parts is no longer guaranteed
if covers are removed. Touching rotating parts can cause sparking with subsequent ignition of
an explosive atmosphere resulting in death, serious injury or material damage.
Carefully ensure that all of the covers are closed while operational.
First switch o󹪜 and disconnect the machine if you must remove covers. Carefully comply with
the "5 safety rules (Page16)".
Only remove the covers when the rotating parts have come to a complete standstill.
Danger as a result of stationary parts under voltage (live parts)
Live parts represent a hazard. Touch protection against active (live) parts is no longer
guaranteed if covers are removed. The minimum air and creepage distances may be fallen below
(violated) when coming close to active parts. Touching or coming close can result in death,
serious injury or material damage.
Carefully ensure that all of the covers are closed while operational.
First switch o󹪜 and disconnect the machine if you must remove covers. Carefully comply with
the "5 safety rules" (Page16).
In operation, the terminal box must always be kept closed. It is only permissible to open the
terminal box when the motor is stationary and in a no voltage condition.
1MB..1/2/3/4 - shaft heights 63 ... 355
Operating Instructions, 11/2023, A5E52779900A 103

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS XP 1MB 1 Series and is the answer not in the manual?

Siemens SIMOTICS XP 1MB 1 Series Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS XP 1MB 1 Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals