Thermal protection (Page51)
6.7 Final checks
Before closing the terminal box/terminal base of the machine enclosure, check the following:
Establish the electrical connections in the terminal box in accordance with the information
in this documentation.
Maintain the air clearances between non-insulated parts as described in Chapter Minimum
air clearances. (Page92)
Avoid protruding wire ends.
In order not to damage the cable insulation, freely arrange the connecting cables.
Connect the machine corresponding to the speci󹪝ed direction of rotation.
Keep the inside of the terminal box clean and free from trimmed-o󹪜 ends of wire.
Ensure that all seals and sealing surfaces are undamaged and clean.
Correctly and professionally close unused openings in the terminal boxes. Observe the
information in this documentation.
Observe the information on torques in this documentation.
See also
Tightening torques for screw and bolt connections (Page169)
Electrical connection
6.7Final checks
1MB..1/2/3/4 - shaft heights 63 ... 355
94 Operating Instructions, 11/2023, A5E52779900A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS XP 1MB 1 Series and is the answer not in the manual?

Siemens SIMOTICS XP 1MB 1 Series Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS XP 1MB 1 Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals