4.5.3 Temperature limits during storage
The materials used are specially designed for the temperature range required by the customer.
The relevant temperature limits are speci󹪝ed on the rating plate.
WARNING
Risk of explosion due to damaged sealing materials
Storing machines at temperatures that do not fall within the speci󹪝ed limits can damage the
material of the seals and cause them to no longer seal correctly. The certi󹪝ed type of protection
of the machine can no longer be complied with.
As a result, a potentially explosive gaseous atmosphere can enter the machine and be ignited
during commissioning. Explosions can occur. This can result in death, serious injury or material
damage.
Do not store the machine in conditions that lie outside the speci󹪝ed temperature limits.
Storage temperature
Permissible temperature range: -20°C to +50°C
Maximum permissible air humidity: 60%
For machines that have a special design regarding the ambient temperature in the operating
state or the installation altitude, other conditions could apply regarding the storage
temperature. In this case, refer to the machine rating plate for data on the ambient
temperature and installation altitude.
Storage time
Turn the shaft once every year to avoid bearing brinelling. Prolonged storage periods reduce the
useful life of the bearing grease (aging).
Open bearings
For open bearings, e.g. 1Z, check the status of the grease when stored for longer than 12
months.
Replace the grease if it is identi󹪝ed that the grease has lost its lubricating properties or is
polluted. The consistency of the grease will change if condensation is allowed to enter.
Closed bearings
For closed bearings, replace the DE and NDE bearings after a storage time of 48 months.
Preparing for use
4.5Transport and storage
1MB..1/2/3/4 - shaft heights 63 ... 355
46 Operating Instructions, 11/2023, A5E52779900A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS XP 1MB 1 Series and is the answer not in the manual?

Siemens SIMOTICS XP 1MB 1 Series Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS XP 1MB 1 Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals