3. If it runs perfectly, connect a load.
NOTICE
Thermal overload of motors connected directly to the line supply
In addition to the load torque, the ramp-up (accelerating) time is essentially in󹪞uenced by
the moment of inertia to be accelerated. While ramping up when connected to the line
supply, the inrush (starting) current is a multiple of the rated current. This can result in
thermal overload. This can damage the motor.
As a consequence, when ramping up, observe the following:
Monitor the ramp-up time and number of consecutive starts.
Comply with the limit values and/or ramp-up conditions speci󹪝ed in the catalog or the
order documentation.
4. During the test run, check and document the following:
Check whether it is running smoothly.
Document the voltage, current and power values. As far as possible, document the
corresponding values of the driven machine.
If this is possible using the available measuring equipment, check the bearing and stator
winding temperatures until they have reached steady-state values.
Check mechanical operation for noise or vibration at the bearings or end shields.
5. In case of uneven running or abnormal noise, switch o󹪜 the machine. As the machine runs
down, identify the cause.
If the mechanical operation improves immediately after the machine is switched o󹪜, then
the cause is magnetic or electrical.
If the mechanical running does not improve immediately after switching the machine
o󹪜, then the cause is mechanical.
- Imbalance of the electrical machine or the driven machine
- The machine set has not been adequately aligned
- The machine is being operated at the system resonance point. System = motor, base
frame, foundation, ...
NOTICE
Destruction of the machine
If the vibration values in operation are not maintained in accordance with ISO 10816-3,
then the machine can be mechanically destroyed.
In operation, maintain vibration values in accordance with ISO10816‑3.
Commissioning
7.3Switching on
1MB..1/2/3/4 - shaft heights 63 ... 355
Operating Instructions, 11/2023, A5E52779900A 101

Table of Contents

Questions and Answers: