Application examples
Example Possible solution
When replacing the pressure cylinders of the plates, it is only
permissible that the drive moves in the safe direction.
Select SDI in the inverter via a
fail-safe digital input or via
PROFIsafe.
In the inverter, inhibit the
direction of rotation that is not
permitted.
After a protective device to detect a jammed door responds, a
rolling shutter gate may only move in the opening direction.
When a crane trolley is at the operating limit switch then it may
only start in the opposite direction.
To manually clean the roller in a printing machine, the roller must
only turn in a specific direction.
Description
3.7 An overview of the principle of operation of the safety functions
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD 43

Table of Contents

Other manuals for Siemens SINAMICS G120C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C and is the answer not in the manual?

Siemens SINAMICS G120C Specifications

General IconGeneral
Communication InterfacesPROFINET, PROFIBUS, USS, Modbus RTU
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Storage Temperature-40°C to +70°C
Power Range0.55 kW to 132 kW
Voltage Range380 V to 480 V
Output Voltage0 V to Supply Voltage
Frequency Range0 Hz to rated output frequency
Control ModesVector control with encoder
ProtectionOverload, overvoltage, undervoltage, short circuit, ground fault
Relative Humidity5% to 95%, non-condensing
AltitudeUp to 2000 m without derating