8.5.3 Safe Stop 1 (SS1) and Safe Brake Control (SBC)
The response time of the SS1 function is the time between selecting the SS1 function and the
STO function becoming active.
Response times when selected via PROFIsafe
00
5HFHLYH352),VDIH
WHOHJUDP
6HOHFW66
66LVDFWLYH
672LVDFWLYH
66UHVSRQVHWLPH
2XWSXW
6%&UHVSRQVHWLPH
0RWRUKROGLQJEUDNHLVWRSHQ
6SHHG
%UDNHFORVLQJ
WLPH
7
W
W
W
W
6DIH%UDNH5HOD\
W
W
W
Figure 8-3 Response times when selected via PROFIsafe
Table 8-6 Response times when using the basic functions
Function Selection
via
Response Response time
Worst case for a fault-free in‐
verter
Worst case for an inverter fault
SS1 PROFIBUS STO is ac‐
tive
14 ms + T
2)
14 ms + T
2)
PROFINET 14 ms + T
2)
+ bus cycle time
1)
14 ms + T
2)
+ bus cycle time
1)
SBC PROFIBUS Signal
change at
the output
of the Safe
Brake Relay
16 ms + T
2)
30 ms + T
2)
PROFINET 16 ms + T
2)
+ bus cycle time
1)
30 ms + T
2)
+ bus cycle time
1)
1)
Bus cycle time: Time for cyclic data exchange via PROFINET
2)
T = p9652
System properties
8.5 Response times after selection
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
376 Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD

Table of Contents

Other manuals for Siemens SINAMICS G120C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C and is the answer not in the manual?

Siemens SINAMICS G120C Specifications

General IconGeneral
Communication InterfacesPROFINET, PROFIBUS, USS, Modbus RTU
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Storage Temperature-40°C to +70°C
Power Range0.55 kW to 132 kW
Voltage Range380 V to 480 V
Output Voltage0 V to Supply Voltage
Frequency Range0 Hz to rated output frequency
Control ModesVector control with encoder
ProtectionOverload, overvoltage, undervoltage, short circuit, ground fault
Relative Humidity5% to 95%, non-condensing
AltitudeUp to 2000 m without derating

Related product manuals