Acceptance test and acceptance report
10.2 Acceptance test structure
Safety Integrated
252 Function Manual, 05/2010, A5E03264275A
1. General testing of actual value acquisition
After exchanging the component, initial activation and brief operation in both
directions.
WARNING
During this process, all personnel must keep out of the danger area.
2. Test of failsafe actual value acquisition
Only necessary if Extended Functions are used
If the motion monitoring functions are activated (e.g. SLS or SSM with hysteresis),
briefly operate the drive in both directions.
E) Conclusion of the report
Report of the commissioning status tested and countersignatures
1. Extension of checksums (for each drive)
2. Countersignature