Acceptance test and acceptance report   
10.5 Acceptance tests 
  Safety Integrated 
304  Function Manual, 05/2010, A5E03264275A 
SLS with stop response "STOP B" 
Table 10- 25  Function "Safely-Limited Speed without encoder" with "STOP B"  
No.  Description  Status 
Note: 
The acceptance test must be carried out separately for each configured control and each SLS speed limit used.  
Control may be via TM54F or PROFIsafe. 
Initial state 
•  Drive in "Ready" state (p0010 = 0) 
 
•  Safety Integrated Extended Functions enabled (p9601.2 = 1) 
 
•  Safety functions enabled (p9501.0 = 1) 
 
•  Safety configured without encoder (p9506 = 1) 
 
1. 
•  No Safety faults and alarms (r0945[0...7], r2122[0...7], r9747[0...7]); see note "non-
critical alarms" in section "Acceptance tests". 
 
2.  It may be necessary to take measures in the higher-level control to be able to exceed the active speed limit 
Configure and activate trace recording 
•  Trigger: Trigger on variable - bit pattern (r9722.7 = 0) 
 
•  Record the following values: r9714[0], r9714[1], r9720, r9721, r9722 
 
•  Select the time interval and pretrigger so you can recognize when the active SLS 
limit has been exceeded and the subsequent drive responses 
 
Select SLS with level x 
Switch on the drive and specify the setpoint above the SLS limit 
•  Check that the drive is moving, and after the SLS limit (p9331[x]/9531[x]) has been 
exceeded that it is decelerated along the OFF3 ramp before STOP A becomes 
active 
 
Check whether the following Safety messages are pending: 
•  C01714 (x00), C30714 (x00); x = 1...4 depending on the SLS level (safely limited 
speed exceeded) 
 
•  C01701, C30701 (STOP B initiated) 
 
3. 
•  C01700, C30700 (STOP A initiated) 
 
Analyze trace: 
•  If r9714[0] (unit [µm/Safety clock cycle] or [m°/Safety clock cycle]) exceeds the 
active SLS limit, a Safety message (r9722.7 = 0) becomes active 
 
•  A STOP B is initiated as a consequence (with subsequent stop STOP A) 
 
For better analysis, display the following bit values: 
•  r9720.4 (deselection SLS) and r9720.9/.10 (selection SLS level) 
 
•  r9721.12 (STOP A or B active) 
 
•  r9722.0 (STO active; set for STOP A) 
 
•  r9722.1 (SS1 active; set for STOP B) 
 
•  r9722.4 (SLS active) and r9722.9/.10 (active SLS level) 
 
4. 
•  r9722.7 (internal event; set with the occurrence of the first Safety message)