Tables
12.4 List of predefined subprograms
Fundamentals
Programming Manual, 10.2004 Edition, 6FC5 298-7AB00-0BP1
12-55
25. Synchronous spindle
1st para-
meter
2nd
para-
meter
3rd para-
meter
4th para-
meter
5th parameter 6th
parameter
Explanation
COUPDEF
#
AXIS:
Followin
g axis
AXIS:
Leadin
g axis
REAL:
Counter
transfor
mation
ratio
(FA)
REAL:
Denomin
ator
transfor
mation
ratio
(LA)
STRING[8]: Block change behavior:
"NOC": no block change control,
block change is enabled
immediately, "FINE": block change
on "synchronism fine", "COARSE":
block change on synchronism
coarse and "IPOSTOP": block
change in setpoint-dependent
termination of overlaid movement. If
the block change behavior is not
specified, the set behavior is
applicable and there is no change.
STRING[2]:
"DV":
Setpoint
coupling
"AV":
Actual-
value
coupling
Couple
definition:
definition of
synchronized
spindle
grouping
COUPDEL # AXIS:
Followin
g axis
AXIS:
Leadin
g axis
Couple
delete:
Delete
synchronous
spindle
group
COUPRES
#
AXIS:
Followin
g axis
AXIS:
Leadin
g axis
Couple reset:
Reset
synchronous
spindle
group.
The pro-
grammed
values
become
invalid. The
machine
data values
are valid.
For synchronous spindles, the axis parameters are programmed with SPI(1) or S1.