Detailed Description
2.2 Feedrate FA for positioning axes
Feeds (V1)
2-22 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Parameter: Feed value
Value range
0.001...999,999.999 mm/min, degrees/min or 0.001, ...39 999,9999 inch/min
For more information about the value range of the axial feedrate see:
References:
/PA/ Programming Guide, Fundamentals"
/FB/ Description of Functions, Basic Machine; Velocities, Setpoint/Actual-Value Systems,
Closed-Loop Control (G2)
NC/PLC interface (channel-specific)
The feedrate is output at the channel-specific NC/PLC interface:
DB21, ... DBB158 - DBB193
For a description of the channel-specific NC/PLC interface signals (modification signal,
machine axis number of positioning axis, etc.) see:
References:
/FB/Description of Functions, Basic Machine; Various Interface Signals and Functions
(A2)
NC/PLC interface (axis-specific)
The feed value is output at the axis-specific NC/PLC interface:
DB31, ... DBB78 - DBB81
Note
Maximum axis velocity
The maximum axis velocity is not exceeded:
MD32000 $MA_MAX_AX_VELO (maximum axis velocity)
F function output to the NC/PLC interface
Output of the F functions to the NC/PLC interface is not recommended. Activating the
output of F functions to the NC/PLC interface can cause a drop in velocity in continuous-
path mode. The output of F functions to the NC/PLC interface can be suppressed:
MD22240 $MC_AUXFU_F_SYNC_TYPE (output time of the F functions)
For a detailed description please refer to:
References:
/FB/ Description of Functions - Basic Machine, Auxiliary Functions (H2)
RESET response
After end of program or NC-RESET, the feedrate value takes effect depending on machine
data:
MD22410 $MC_F_VALUES_ACTIVE_AFTER_RESET = <value>
Value Meaning
0 After NC RESET the default values are effective.
1 After NC RESET the last FA values to be programmed are effective.

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals